0021
Upper bake relay shorted on a Wolf M-Series wall oven.
Oven
01
Door-lock malfunction on a Wolf range — the oven lock was not sensed in time.
Range
02
Over-temperature shutdown on a Wolf range oven — the cavity ran too hot.
Range
03
Open RTD oven sensor on a Wolf range — the temperature sensor circuit is open.
Range
04
Shorted RTD oven sensor on a Wolf range — near-zero sensor resistance.
Range
0821
Motorized door-lock (MDL) relay shorted on a Wolf M-Series wall oven.
Oven
0E
Power relay shorted or stuck on a Wolf range oven control.
Range
22
Stuck key on a Wolf CE electric radiant cooktop.
Cooktop
3
Liquid or cookware on the controls of a Wolf CI induction cooktop.
Cooktop
3031
Food probe shorted on a Wolf M-Series wall oven (on-screen "Probe Shorted").
Oven
3121
Oven RTD sensor shorted on a Wolf M-Series wall oven.
Oven
3221
Oven RTD sensor open on a Wolf M-Series wall oven.
Oven
39
Controller options problem on a Wolf CE electric radiant cooktop.
Cooktop
4421
Cooling fan not detected on a Wolf M-Series wall oven.
Oven
4531
Convection fan not detected on a Wolf M-Series wall oven.
Oven
47
LIN communication problem on a Wolf CE electric radiant cooktop.
Cooktop
5021
Over-temperature during self-clean (>950°F) on a Wolf M-Series wall oven.
Oven
8010
Display failure on a Wolf M-Series wall oven touchscreen.
Oven
9010
Touch-sensor failure on a Wolf M-Series wall oven ("Touch Pad Sensor failure").
Oven
Blower Won’t Run
A Wolf range hood blower will not run on any speed.
Range Hood
Blown Monitor Fuse
A Wolf microwave is dead from a blown monitor fuse — a door-interlock safety issue.
Microwave
Brownout
Brownout / low-voltage error on a Wolf E-Series wall oven.
Oven
Burner Won’t Ignite
A Wolf SRT rangetop burner clicks or does nothing but will not light.
Range Top
COMM ERR
Communication lost with the oven controller on a Wolf range.
Range
Communications Error
UIM/RM communication failure between boards on a Wolf E-Series wall oven.
Oven
Continuous Clicking
A Wolf gas range keeps clicking, sometimes on every burner, even after lighting.
Range
Continuous Clicking
A Wolf SRT rangetop keeps clicking — often all burners at once.
Range Top
Convection Fan Failure
The convection fan on a Wolf range oven is silent, noisy, or not circulating heat.
Range
COOL FAN
Cooling-fan failure on a Wolf range — the control electronics may overheat.
Range
Door Won’t Unlock
A Wolf wall oven door stays locked after a self-clean cycle.
Oven
Downdraft Won’t Raise
A Wolf downdraft (DD) ventilation unit will not raise or lower.
Range Hood
Drawer Won’t Close
A Wolf microwave drawer (MD) will not close or seal fully.
Microwave
Drawer Won’t Open
A Wolf microwave drawer (MD) will not open when the button is pressed.
Microwave
E01
Ambient temperature too high on a legacy Wolf CT electric cooktop.
Cooktop
E02
Heatsink temperature high on a legacy Wolf CT electric cooktop.
Cooktop
E05
Open ambient thermistor on a legacy Wolf CT electric cooktop.
Cooktop
E07
Model/configuration value changed on a legacy Wolf CT electric cooktop.
Cooktop
E08
Keyboard communication problem on a legacy Wolf CT electric cooktop.
Cooktop
E09
PT temperature-sensor short on a Wolf CSO convection steam oven.
Oven
E09
Keyboard communication problem on a legacy Wolf CT electric cooktop.
Cooktop
E1
Ambient temperature too high on a legacy Wolf CT induction cooktop.
Cooktop
E10
Generator communication problem on a legacy Wolf CT induction cooktop.
Cooktop
E17 / F1
Food-probe short on a Wolf CSO convection steam oven (shown as E17/F1).
Oven
E18
Food-probe resistance too high on a Wolf CSO convection steam oven.
Oven
E18
Power-board failure on a legacy Wolf CT electric cooktop.
Cooktop
E22
Stuck key on a Wolf CI induction cooktop touch control.
Cooktop
E29 / F9
Steam chamber not sealed on a Wolf CSO convection steam oven (E29/F9).
Oven
E3
Heatsink temperature high on a legacy Wolf CT induction cooktop.
Cooktop
E31
Burner ON-LED failure on a legacy Wolf CT induction cooktop.
Cooktop
E4
Configuration implausible on a Wolf CI induction cooktop.
Cooktop
E4
Heatsink temperature high on a legacy Wolf CT induction cooktop.
Cooktop
E41
Temperature sensor shorted on a legacy Wolf CT induction cooktop.
Cooktop
E43
Induction generator failure on a legacy Wolf CT induction cooktop.
Cooktop
E47
LIN communication problem on a Wolf CI induction cooktop.
Cooktop
E5
Relay failure on a Wolf CE electric radiant cooktop.
Cooktop
E53
Shorted thermistor on a legacy Wolf CT induction cooktop.
Cooktop
E6
Power-supply problem, or no/wrong pan, on a Wolf CI induction cooktop.
Cooktop
E6
Power-supply problem on a Wolf CE electric radiant cooktop.
Cooktop
E8
Cooling-fan error on a Wolf CI induction cooktop.
Cooktop
E8
Cooling-fan error on a Wolf CE electric radiant cooktop.
Cooktop
E8
Generator communication problem on a legacy Wolf CT induction cooktop.
Cooktop
E9
Generator communication problem on a legacy Wolf CT induction cooktop.
Cooktop
EA
Controller problem on a Wolf CI induction cooktop.
Cooktop
EA
Controller problem on a Wolf CE electric radiant cooktop.
Cooktop
F1
Door-lock failure on a Wolf E-Series wall oven — common after a self-clean.
Oven
F4 / E87
Steam generator / temperature-sensor failure on a Wolf CSO steam oven (F4/E87).
Oven
Fan Noise
A Wolf range hood is rattling, humming, or noisy when running.
Range Hood
FC Filter Reminder
FC on a Wolf V-Series range hood is a recirculating-filter reminder, not a problem.
Range Hood
FG Filter Reminder
FG on a Wolf V-Series range hood is a clean-filters reminder, not a problem.
Range Hood
FUSES WRONG
Controller configuration incorrect on a Wolf range — the control is mis-set for the model.
Range
Gas Burner Won’t Ignite
A Wolf gas range surface burner clicks or does nothing but will not light.
Range
Gas Clicks Won’t Ignite
A Wolf CG gas cooktop burner keeps clicking but will not light.
Cooktop
Gas Smell When Off
A Wolf SRT rangetop smells of gas with the burners turned off — a safety issue.
Range Top
Keypad Error
Keypad / membrane circuit error on a Wolf E-Series wall oven.
Oven
Knob Stuck
A Wolf SRT rangetop control knob is stiff, stuck, or hard to turn.
Range Top
Lights Out
The lights on a Wolf range hood do not come on.
Range Hood
LOWER RELAY
Lower-oven relay feedback failure on a Wolf double range.
Range
No Bake Element Detect
No bake element detected on a Wolf E-Series wall oven.
Oven
No Cooling Fan Detect
Cooling fan not detected on a Wolf E-Series wall oven.
Oven
No Power
A Wolf microwave is dead — no display and no response.
Microwave
Oven Won’t Heat
A Wolf range oven runs but never gets hot, or heats far below the set point.
Range
Oven Won’t Heat
A Wolf wall oven powers on but never gets hot or heats far below the set point.
Oven
Over Temp
Over-temperature shutdown on a Wolf E-Series wall oven.
Oven
Pan Not Detected
A Wolf induction cooktop zone will not detect the pan and will not heat.
Cooktop
PF
Power failure or oven-too-hot-for-mode condition on a Wolf range.
Range
Relay Open
A heating relay reads open (stuck off) on a Wolf E-Series wall oven.
Oven
Relay Shorted
A heating relay reads shorted (stuck closed) on a Wolf E-Series wall oven.
Oven
RTD Open
Open oven temperature sensor on a Wolf E-Series wall oven.
Oven
RTD Shorted
Shorted oven temperature sensor on a Wolf E-Series wall oven.
Oven
Single Burner No Spark
One Wolf SRT rangetop burner has no spark while the others ignite.
Range Top
Temp Probe Short
Meat/temperature probe shorted on a Wolf E-Series wall oven.
Oven
Touchpad Unresponsive
A Wolf microwave touchpad does not respond to presses.
Microwave
U400
Over-voltage shutdown on a Wolf CE electric radiant cooktop.
Cooktop
Weak Flame
A Wolf SRT rangetop burner lights but the flame is weak or simmers poorly.
Range Top
Weak Suction
A Wolf range hood runs but pulls smoke and steam weakly.
Range Hood
Won’t Heat
A Wolf microwave runs but does not heat — check Demo/Showroom mode first.
Microwave
Won’t Self-Clean
A Wolf wall oven will not start or finish a self-clean cycle.
Oven
Wolf range error codes (01, 02, 03, 04, PF) explained

How a Wolf range reports a fault

A Wolf range is diagnosed on two fronts — the cooktop and the oven control. On Dual Fuel (DF) and Induction (IR) ranges the electric oven board reports genuine numeric and text codes, so a stalled bake or a stuck self-clean shows a code rather than failing silently. On the all-gas GR oven and on every gas surface burner there is no code, so those faults are read by symptom. The code set below applies to the electric ovens on DF and IR builds.

The codes you will see

01 is a door-lock malfunction — the lock not sensed within 60 seconds, most common right after a self-clean cycle. 02 is an over-temperature trip (around 630°F unlocked or 950°F locked). 03 is an open RTD oven sensor and 04 a shorted RTD sensor — the temperature probe the oven uses to hold a setpoint. 0E is a shorted or stuck power relay on the board. Alongside the numbers, Wolf shows text faults: PF for a power failure or an oven too hot for the selected mode, COMM ERR for lost communication with the oven controller, COOL FAN for a cooling-fan failure, LOWER RELAY for a lower-oven relay feedback fault, and FUSES WRONG for an incorrect controller configuration.

The gas side: read by symptom

The GR all-gas oven and the gas surface burners on every range carry no code. A burner that clicks continuously often has moisture in the igniter well — let it dry for 24 to 48 hours — or clogged ports, a fouled spark module or a failed igniter. A gas oven that will not heat usually points at the oven igniter, and a torn door gasket shows as lost heat. These are diagnosed by what you observe, not by a code.

What to check, and when to call

For an 01 after self-clean, let the oven cool fully and power-cycle at the breaker for 30 to 60 seconds. For a PF, the same reset often clears a one-off power event. A recurring 01, an 02 over-temp, an open or shorted RTD (03/04), a 0E relay fault, a COOL FAN or LOWER RELAY message, or any gas burner that smells of gas with the knob off needs an experienced, independent technician with the correct part. See the full list on the range error codes page or the wider error codes library, then book range repair. Confirm your model on the manufacturer’s site at subzero-wolf.com.

C — Need help?