97 Error codes
6 Appliance types
93 Service areas
139 Models covered

Schedule Wolf
appliance repair

Experienced technicians in all 50 US states. Average response within 24 hours.

  • Experienced Wolf specialists
  • Genuine OEM parts
  • 30-day labor warranty
  • Upfront pricing

Search by code or appliance type.

0021
Upper bake relay shorted on a Wolf M-Series wall oven.
Oven
01
Door-lock malfunction on a Wolf range — the oven lock was not sensed in time.
Range
02
Over-temperature shutdown on a Wolf range oven — the cavity ran too hot.
Range
03
Open RTD oven sensor on a Wolf range — the temperature sensor circuit is open.
Range
04
Shorted RTD oven sensor on a Wolf range — near-zero sensor resistance.
Range
0821
Motorized door-lock (MDL) relay shorted on a Wolf M-Series wall oven.
Oven
0E
Power relay shorted or stuck on a Wolf range oven control.
Range
22
Stuck key on a Wolf CE electric radiant cooktop.
Cooktop
3
Liquid or cookware on the controls of a Wolf CI induction cooktop.
Cooktop
3031
Food probe shorted on a Wolf M-Series wall oven (on-screen "Probe Shorted").
Oven
3121
Oven RTD sensor shorted on a Wolf M-Series wall oven.
Oven
3221
Oven RTD sensor open on a Wolf M-Series wall oven.
Oven
39
Controller options problem on a Wolf CE electric radiant cooktop.
Cooktop
4421
Cooling fan not detected on a Wolf M-Series wall oven.
Oven
4531
Convection fan not detected on a Wolf M-Series wall oven.
Oven
47
LIN communication problem on a Wolf CE electric radiant cooktop.
Cooktop
5021
Over-temperature during self-clean (>950°F) on a Wolf M-Series wall oven.
Oven
8010
Display failure on a Wolf M-Series wall oven touchscreen.
Oven
9010
Touch-sensor failure on a Wolf M-Series wall oven ("Touch Pad Sensor failure").
Oven
Blower Won’t Run
A Wolf range hood blower will not run on any speed.
Range Hood
Blown Monitor Fuse
A Wolf microwave is dead from a blown monitor fuse — a door-interlock safety issue.
Microwave
Brownout
Brownout / low-voltage error on a Wolf E-Series wall oven.
Oven
Burner Won’t Ignite
A Wolf SRT rangetop burner clicks or does nothing but will not light.
Range Top
COMM ERR
Communication lost with the oven controller on a Wolf range.
Range
Communications Error
UIM/RM communication failure between boards on a Wolf E-Series wall oven.
Oven
Continuous Clicking
A Wolf gas range keeps clicking, sometimes on every burner, even after lighting.
Range
Continuous Clicking
A Wolf SRT rangetop keeps clicking — often all burners at once.
Range Top
Convection Fan Failure
The convection fan on a Wolf range oven is silent, noisy, or not circulating heat.
Range
COOL FAN
Cooling-fan failure on a Wolf range — the control electronics may overheat.
Range
Door Won’t Unlock
A Wolf wall oven door stays locked after a self-clean cycle.
Oven
Downdraft Won’t Raise
A Wolf downdraft (DD) ventilation unit will not raise or lower.
Range Hood
Drawer Won’t Close
A Wolf microwave drawer (MD) will not close or seal fully.
Microwave
Drawer Won’t Open
A Wolf microwave drawer (MD) will not open when the button is pressed.
Microwave
E01
Ambient temperature too high on a legacy Wolf CT electric cooktop.
Cooktop
E02
Heatsink temperature high on a legacy Wolf CT electric cooktop.
Cooktop
E05
Open ambient thermistor on a legacy Wolf CT electric cooktop.
Cooktop
E07
Model/configuration value changed on a legacy Wolf CT electric cooktop.
Cooktop
E08
Keyboard communication problem on a legacy Wolf CT electric cooktop.
Cooktop
E09
PT temperature-sensor short on a Wolf CSO convection steam oven.
Oven
E09
Keyboard communication problem on a legacy Wolf CT electric cooktop.
Cooktop
E1
Ambient temperature too high on a legacy Wolf CT induction cooktop.
Cooktop
E10
Generator communication problem on a legacy Wolf CT induction cooktop.
Cooktop
E17 / F1
Food-probe short on a Wolf CSO convection steam oven (shown as E17/F1).
Oven
E18
Food-probe resistance too high on a Wolf CSO convection steam oven.
Oven
E18
Power-board failure on a legacy Wolf CT electric cooktop.
Cooktop
E22
Stuck key on a Wolf CI induction cooktop touch control.
Cooktop
E29 / F9
Steam chamber not sealed on a Wolf CSO convection steam oven (E29/F9).
Oven
E3
Heatsink temperature high on a legacy Wolf CT induction cooktop.
Cooktop
E31
Burner ON-LED failure on a legacy Wolf CT induction cooktop.
Cooktop
E4
Configuration implausible on a Wolf CI induction cooktop.
Cooktop
E4
Heatsink temperature high on a legacy Wolf CT induction cooktop.
Cooktop
E41
Temperature sensor shorted on a legacy Wolf CT induction cooktop.
Cooktop
E43
Induction generator failure on a legacy Wolf CT induction cooktop.
Cooktop
E47
LIN communication problem on a Wolf CI induction cooktop.
Cooktop
E5
Relay failure on a Wolf CE electric radiant cooktop.
Cooktop
E53
Shorted thermistor on a legacy Wolf CT induction cooktop.
Cooktop
E6
Power-supply problem, or no/wrong pan, on a Wolf CI induction cooktop.
Cooktop
E6
Power-supply problem on a Wolf CE electric radiant cooktop.
Cooktop
E8
Cooling-fan error on a Wolf CI induction cooktop.
Cooktop
E8
Cooling-fan error on a Wolf CE electric radiant cooktop.
Cooktop
E8
Generator communication problem on a legacy Wolf CT induction cooktop.
Cooktop
E9
Generator communication problem on a legacy Wolf CT induction cooktop.
Cooktop
EA
Controller problem on a Wolf CI induction cooktop.
Cooktop
EA
Controller problem on a Wolf CE electric radiant cooktop.
Cooktop
F1
Door-lock failure on a Wolf E-Series wall oven — common after a self-clean.
Oven
F4 / E87
Steam generator / temperature-sensor failure on a Wolf CSO steam oven (F4/E87).
Oven
Fan Noise
A Wolf range hood is rattling, humming, or noisy when running.
Range Hood
FC Filter Reminder
FC on a Wolf V-Series range hood is a recirculating-filter reminder, not a problem.
Range Hood
FG Filter Reminder
FG on a Wolf V-Series range hood is a clean-filters reminder, not a problem.
Range Hood
FUSES WRONG
Controller configuration incorrect on a Wolf range — the control is mis-set for the model.
Range
Gas Burner Won’t Ignite
A Wolf gas range surface burner clicks or does nothing but will not light.
Range
Gas Clicks Won’t Ignite
A Wolf CG gas cooktop burner keeps clicking but will not light.
Cooktop
Gas Smell When Off
A Wolf SRT rangetop smells of gas with the burners turned off — a safety issue.
Range Top
Keypad Error
Keypad / membrane circuit error on a Wolf E-Series wall oven.
Oven
Knob Stuck
A Wolf SRT rangetop control knob is stiff, stuck, or hard to turn.
Range Top
Lights Out
The lights on a Wolf range hood do not come on.
Range Hood
LOWER RELAY
Lower-oven relay feedback failure on a Wolf double range.
Range
No Bake Element Detect
No bake element detected on a Wolf E-Series wall oven.
Oven
No Cooling Fan Detect
Cooling fan not detected on a Wolf E-Series wall oven.
Oven
No Power
A Wolf microwave is dead — no display and no response.
Microwave
Oven Won’t Heat
A Wolf range oven runs but never gets hot, or heats far below the set point.
Range
Oven Won’t Heat
A Wolf wall oven powers on but never gets hot or heats far below the set point.
Oven
Over Temp
Over-temperature shutdown on a Wolf E-Series wall oven.
Oven
Pan Not Detected
A Wolf induction cooktop zone will not detect the pan and will not heat.
Cooktop
PF
Power failure or oven-too-hot-for-mode condition on a Wolf range.
Range
Relay Open
A heating relay reads open (stuck off) on a Wolf E-Series wall oven.
Oven
Relay Shorted
A heating relay reads shorted (stuck closed) on a Wolf E-Series wall oven.
Oven
RTD Open
Open oven temperature sensor on a Wolf E-Series wall oven.
Oven
RTD Shorted
Shorted oven temperature sensor on a Wolf E-Series wall oven.
Oven
Single Burner No Spark
One Wolf SRT rangetop burner has no spark while the others ignite.
Range Top
Temp Probe Short
Meat/temperature probe shorted on a Wolf E-Series wall oven.
Oven
Touchpad Unresponsive
A Wolf microwave touchpad does not respond to presses.
Microwave
U400
Over-voltage shutdown on a Wolf CE electric radiant cooktop.
Cooktop
Weak Flame
A Wolf SRT rangetop burner lights but the flame is weak or simmers poorly.
Range Top
Weak Suction
A Wolf range hood runs but pulls smoke and steam weakly.
Range Hood
Won’t Heat
A Wolf microwave runs but does not heat — check Demo/Showroom mode first.
Microwave
Won’t Self-Clean
A Wolf wall oven will not start or finish a self-clean cycle.
Oven
Understanding Wolf error codes

How a Wolf appliance reports a problem

Wolf cooking appliances differ sharply in how much they tell you, and knowing which of the six categories you own is the first step to an accurate repair. Electric-oven ranges and every wall oven carry a genuine error-code set; induction and electric cooktops surface a thin set of numeric codes; and gas surfaces, rangetops, microwaves and range hoods have no consumer code table at all, so they are diagnosed from symptoms. Reading the right signal points an experienced technician at a specific part — a sensor, a relay, the door lock or the control board — while a symptom points at the burner, the igniter, the gas supply, the filter or a mode left running. This page explains the genuine signals Wolf uses; each appliance type also has its own detailed breakdown in the error codes library.

Range oven codes (Dual Fuel and Induction)

On a Wolf Dual Fuel (DF) or Induction (IR) range, the electric oven control reports real codes. 01 is a door-lock malfunction (the lock not sensed within 60 seconds — common after a self-clean cycle); 02 is an over-temperature trip; 03 is an open RTD oven sensor and 04 a shorted one; and 0E is a shorted or stuck power relay. Text problems round out the set — PF for a power failure or an oven too hot for the selected mode, COMM ERR for lost communication with the oven controller, COOL FAN for a cooling-fan failure, and LOWER RELAY for a lower-oven relay feedback problem. The all-gas GR oven and every gas surface burner have no code and are read by symptom. The full list is on the range error codes page.

Wall oven codes (three separate schemes)

Wolf wall ovens are the most code-rich Wolf appliances, and they use three schemes that must never be mixed. The legacy E Series reports text phrases plus the F1 door-lock failure — for example “RTD Open”, “Over Temp”, “No Bake element detect” or a keypad communication error. The current M Series uses four-digit numeric codes where the first digit groups the problem — 0021/0022 a bake relay, 0821/0822 the lock relay, 31213222 the RTD, 5021/5121 over-temperature — alongside on-screen messages such as “Touch Pad Sensor failure”. The CSO Convection Steam oven uses paired codes such as E17/F1 (food-probe short) and E29/F9 (chamber not sealed). See the oven error codes page, and always identify the series first.

Cooktop codes (induction and electric)

Wolf induction (CI) and electric-radiant (CE) cooktops surface a thin set of stored codes. On induction, 3 means liquid or cookware over the controls, E4 an implausible configuration, E6 an electrical or power-supply issue (also Wolf’s no/wrong-pan signal — use flat magnetic cookware), E8 a fan error and E22 a stuck key. On electric radiant, 22 is a stuck key, E5 a relay failure, E6 a power-supply problem, E8 a fan error and U400 an over-voltage condition. The sealed-gas (CG) cooktops and legacy CT gas builds have no display and are diagnosed by symptom. The cooktop error codes page lists the verified set.

The categories diagnosed by symptom

Three Wolf categories carry no error codes and are read entirely from behavior. The SRT rangetop is a gas surface controlled by mechanical knobs and spark ignition with no display, so a burner that will not light, clicks continuously without sparking or burns yellow is the diagnostic itself — and because all burners share one spark module, continuous clicking on every burner points there. Microwaves show status words rather than codes — DEMO (showroom mode, which disables heating and is the most common reason a new install “won’t heat”), PF, LOCK and END. Range hoods are symptom-led too; the only display text on the V-Series is the filter-clean reminder FG (vented) or FC (recirculating) after about 100 hours — a maintenance prompt, not a problem, and there is no F6. The symptom pages walk through these checks for the rangetop, the microwave and the range hood.

When to reset and when to call

For many problems the homeowner step is the same: power-cycle the appliance — switch the breaker off for 30 to 60 seconds — and watch the panel. A post-self-clean door-lock code, a microwave in demo mode, a filter-clean reminder or a one-off alarm usually clears or resolves with simple maintenance. A persistent RTD sensor or relay failure, a stuck door lock, a cooling-fan failure, a recurring over-temperature trip, or a gas burner that will not light or smells of gas with the knob off calls for an experienced technician with the correct parts. We are an independent service, not affiliated with Wolf or Sub-Zero; our technicians diagnose every Wolf signal across ranges, ovens, rangetops, cooktops, microwaves and range hoods, and you can confirm your model on the manufacturer’s site at subzero-wolf.com. When you are ready, schedule your repair and our team will confirm the next available visit.